Geil MD. Consistency, precision, and accuracy of optical and electromagnetic shape-capturing systems for digital measurement of residual-limb anthropometrics of persons with transtibial amputation. Journal of Rehabilitation Research and Development. 44(4), 515-524, 2007. (full pdf)
Sawers A, Parsons S, Geil MD, Hovorka C. Positive model temperature and its effect on stiffness and percent crystallinity of polypropylene. Journal of Prosthetics and Orthotics. 19(3), 75-83, 2007.
Hovorka CF, Geil MD, Lusardi M. “Principles Influencing Orthotic and Prosthetic Design: Biomechanics, Device-User Interface, and Related Concepts,” in Orthotics and Prosthetics in Rehabilitation. 2nd ed. St. Louis: Saunders Elsevier, 2007. 99. 135-154.
Plank LH, Giavedoni B, Lombardo JR, Geil MD, Reisner A. Comparison of infant head shape changes in deformational plagiocephaly following treatment with a cranial remolding orthosis using a non-invasive laser shape digitizer. Journal of Craniofacial Surgery. 17(6), 1084-1091, 2006.
Parente MA, Geil MD. “In the future: Surgical and educational advances and challenges,” in Prosthetics and Patient Management: A Comprehensive Clinical Approach. Thorofare, NJ: Slack Incorporated, 2006. pp. 225-234.
Parente MA, Geil MD, Monroe, B. “In the future: Prosthetic advances and challenges,” in Prosthetics and Patient Management: A Comprehensive Clinical Approach. Thorofare, NJ: Slack Incorporated, 2006. pp. 207-224.
Geil, MD. Consistency and accuracy of measurement of lower extremity amputee anthropometrics. Journal of Rehabilitation Research and Development. 42(2), 131-140, 2005. (pdf online)
Geil, MD, Lay, AM. Plantar foot pressure responses to changes during dynamic transtibial alignment in a clinical setting. Prosthetics and Orthotics International. 28, 105-114, 2004.
Geil, MD. An iterative method for viscoelastic modeling of prosthetic Feet. Journal of Biomechanics. 35(10), 1405-1410, 2002.
Geil, MD. Variability among practitioners in dynamic observational alignment of a transfemoral prosthesis. Journal of Prosthetics and Orthotics. 14(4), 159-164, 2002.
Geil MD. The role of footwear on kinematics and plantar foot pressure in fencing. Journal of Applied Biomechanics. 18(2), 155-162, 2002.
Geil MD. Energy loss and stiffness properties of dynamic elastic response prosthetic feet. Journal of Prosthetics and Orthotics. 13(3), 70-73, 2001.
Geil, MD. “Energy Storage and Return in Dynamic Elastic Response Prosthetic Feet,” in Pediatric Gait: A New Millennium in Clinical Care and Motion Analysis Technology. Harris, Gerald F and Peter A Smith, eds. New Jersey: IEEE Press, 2000. pp. 134-142.